Linear registration to stereotaxic space is a common first step in many automated image-processing tools for analysis of human brain MRI scans. This step is crucial for the success of the subsequent image-processing steps. Several well-established algorithms are commonly used in the field of neuroimaging for this task, but none have a 100% success rate. Manual assessment of the registration is commonly used as part of quality control. To reduce the burden of this time-consuming step, we propose Deep Automated Registration Qc (DARQ), a fully automatic quality control method based on deep learning that can replace the human rater and accurately perform quality control assessment for stereotaxic registration of T1w brain scans.

In a recently published study from our group comparing linear registration methods, we used a database of 9325 MRI scans from several publicly available datasets and applied seven linear registration tools to them. In this study, the resulting images that were assessed and labeled by a human rater are used to train a deep neural network to detect cases when registration failed. We further validated the results on an independent dataset of patients with multiple sclerosis, with manual QC labels available (n=1200).

In terms of agreement with a manual rater, our automated QC method was able to achieve 89% accuracy and 85% true negative rate (equivalently 15% false positive rate) in detecting scans that should pass quality control in a balanced cross-validation experiments, and 96.1% accuracy and 95.5% true negative rate (or 4.5% FPR) when evaluated in a balanced independent sample, similar to manual QC rater (test-retest accuracy of 93%).

The results show that DARQ is robust, fast, accurate, and generalizable in detecting failure in linear stereotaxic registrations and can substantially reduce QC time (by a factor of 20 or more) when processing large datasets.

Go back to top